New Free consultation: describe your project, we reply in writing → info@ranieritech.com| Request a quote
Log in Quote
Technical standard · Machinery safety

EN ISO 13849-1: safety-related parts of control systems

EN ISO 13849-1 sets out how to design and evaluate the parts of control systems that perform safety functions, such as stopping when a guard is opened. It is for machine builders who must show that each safety function has the reliability required by the risk it is meant to reduce. It applies to different technologies: mechanical, pneumatic, hydraulic and electrical.

From risk assessment to the safety function

The starting point is the risk assessment to EN ISO 12100. When a protective measure depends on the control system, the standard requires you to describe the safety function: what it must do, in which operating modes, with what response times and which safe state it must reach.

For each function you then establish the required performance level, the PLr, and check that the actual system achieves a PL at least equal to it.

Two-hand control device on a stand
Two-hand control device on a stand · Photo: Sam D. Wilbur, CC BY 4.0, Wikimedia Commons

PLr from the risk graph

The PLr is determined with a risk graph based on three parameters. The result is one of five levels, from a, the least demanding, to e, the most demanding.

The 2023 edition clarified some aspects of parameter selection and of the possibility of taking the probability of the hazardous event into account: always check which edition you are applying.

  • S, severity of injury: S1 slight and normally reversible, S2 serious and normally irreversible, including death.
  • F, frequency or duration of exposure to the hazard: F1 seldom or short, F2 frequent or long.
  • P, possibility of avoiding the hazard or limiting the harm: P1 possible under certain conditions, P2 scarcely possible.

How the achieved PL is estimated

The achieved PL depends on several factors together. With the simplified method of the standard, category, MTTFd and DCavg are combined in a bar chart, provided that the measures against common cause failures are sufficient. Each PL corresponds to a range of average probability of dangerous failure per hour.

  • Category: B, 1, 2, 3 or 4, i.e. the architecture and the behaviour in the event of a fault. Categories 3 and 4 use two channels; category 4 requires single faults to be detected so that they do not lead to loss of the function.
  • MTTFd: mean time to dangerous failure of each channel, classified as low, medium or high. For components subject to wear, such as valves and limit switches, it is calculated from the B10d and the number of operations per year.
  • DCavg: average diagnostic coverage, i.e. the share of dangerous failures that the system is able to detect, from none to high.
  • CCF: measures against common cause failures, assessed with a scoring table; for categories 2, 3 and 4 at least the minimum score given in the standard is required.
Principle diagram: EN ISO 13849-1 / -2
Principle diagram: EN ISO 13849-1 / -2

Validation with EN ISO 13849-2

Part 2 describes validation: analysis and testing to confirm that each safety function does what is specified and achieves the declared PL. It also contains lists of basic and well-tried safety principles, and of faults to be considered or excluded for mechanical, pneumatic, hydraulic and electrical components.

Fault exclusions must be justified one by one. They are common in mechanical systems, but must not be taken for granted.

Documents to prepare and common mistakes

For each safety function you need the specification, the PLr with the reasoning behind the parameters, the block diagram of the channels, the component data, the calculation of MTTFd, DCavg and CCF, the achieved PL and the validation plan. The studio can carry out the PL calculation and prepare this documentation starting from the diagrams and component data you provide.

The most common mistakes are using the PL declared for a single component as the PL of the function, leaving the position switch or the valve out of the calculation, estimating the annual number of operations too optimistically and not considering common cause failures.

Frequently asked questions

What is the difference between PL and SIL?

PL is the measure used by EN ISO 13849-1, SIL the one used by IEC 62061. The two standards use different methods, but for many machinery safety functions they lead to comparable results.

If I buy a component certified PL e, is the function PL e?

No. The PL refers to the whole function, from the input through the logic to the actuator. A PL e component connected to an actuator in a single channel without diagnostics does not guarantee PL e.

How do you calculate the MTTFd of a pneumatic valve?

You start from the B10d given by the manufacturer and the average number of operations per year. The MTTFd is obtained by dividing the B10d by one tenth of the annual number of operations.

Does EN ISO 13849-1 also apply to purely pneumatic or hydraulic systems?

Yes. The standard is technology-independent, and part 2 lists specific faults and exclusions for pneumatic and hydraulic components.

Summary for information only: the requirements are those of the official text of the standard in its current edition, available from the standards bodies. Ranieri — Servizi di ingegneria covers the mechanical side and does not carry out work reserved to members of a professional register.